Sign in →

Test ID: BUAUC Busulfan, Intravenous Dose, Area Under the Curve, Plasma

Reporting Name

Busulfan, IV Dose, AUC, P

Useful For

Guiding dosage adjustments to achieve complete bone marrow ablation while minimizing dose-dependent toxicity

Profile Information

Test ID Reporting Name Available Separately Always Performed
DOSE Busulfan, IV Dose, AUC, P No Yes
BU2H Busulfan, Immediate Post Infusion No Yes
BU3H Busulfan, 1hr Post Infusion No Yes
BU4H Busulfan, 2hr Post Infusion No Yes
BU6H Busulfan, 4hr Post Infusion No Yes

Specimen Type

Plasma Na Heparin


Necessary Information


The time the drug administration is started and completed, the patient's dose (mg every 6 hours), body weight (kg), and age (years) must be submitted with the specimens. Without infusion start time, exact time of specimen collection, dose, and body weight, the area under the curve and clearance cannot be calculated. Age is required for assessment of the correct dose per body weight.

 

A completed Busulfan Information: Mail-In Specimen Instructions (T559) is required.



Specimen Required


Four plasma specimens with different collection times (keep all specimens under 1 order) are required.

 

Collection Container/Tube: Green top (sodium heparin) (Plasma gel/PST are not acceptable)

Submission Container/Tube: Plastic vials

Specimen Volume: 1 mL

Collection Instructions:

1. The first specimen should be collected immediately after completion of the first intravenous infusion of 0.8 mg/kg busulfan.

2. Additional specimens should also be collected at 1 hour, 2 hours, and 4 hours after completion of infusion.

3. Label each specimen with exact time of collection.

4. Busulfan degrades quickly at ambient temperature. Specimens must be kept in wet ice slurry or refrigerated at 4° C. Specimens must be centrifuged within 2 hours after collection. Separate the plasma and transfer to individual 5-mL plastic vials, labeled with exact time of collection. Immediately freeze at -20° C.

Additional Information:

This test should only be ordered when the following criteria are met:

-Busulfan dosing protocol must be intravenous administration of 0.8 mg/kg doses every 6 hours over 4 days, for a total of 16 doses

Specimens must be collected as described below:

-1 specimen collected immediately after completion of the first 2-hour IV infusion of busulfan

-1 specimen collected 1 hour after the infusion is completed

-1 specimen collected 2 hours after the infusion is completed

-1 specimen collected 4 hours after the infusion is completed and prior to the next infusion of busulfan


Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Plasma Na Heparin Frozen (preferred) 28 days
  Refrigerated  72 hours

Reference Values

AREA UNDER THE CURVE

900-1500 (mcmol/L)(min)

 

CLEARANCE

2.1-3.5 (mL/minute)/kg

Day(s) Performed

Monday through Saturday

CPT Code Information

80299 x 4

LOINC Code Information

Test ID Test Order Name Order LOINC Value
BUAUC Busulfan, IV Dose, AUC, P 93478-6

 

Result ID Test Result Name Result LOINC Value
DRDT2 Draw Date 33882-2
DRDT3 Draw Date 33882-2
DRDT4 Draw Date 33882-2
DRDT6 Draw Date 33882-2
DSE Initial Dose 93477-8
DAT16 Infusion Start Date 88063-3
DRTM6 Draw Time 49049-0
DRTM4 Draw Time 49049-0
DRTM3 Draw Time 49049-0
DRTM2 Draw Time 49049-0
24221 Busulfan result 93436-4
24222 Busulfan result 93435-6
24223 Busulfan result 93434-9
24224 Busulfan result 93433-1
TM82 Infusion Start Time 88060-9
DAT17 Infusion Stop Date 88062-5
TM65 Infusion Stop Time 88061-7
W8 Weight 29463-7
24220 Age 30525-0
24225 Area Under the Curve, (0-6 Hour) 93476-0
24226 Clearance 93475-2
24227 Recommended Dose 93477-8

Clinical Information

Busulfan is an alkylating agent used to ablate bone marrow cells prior to hematopoietic stem cell transplantation for chronic myelogenous leukemia.(1) Busulfan is typically administered intravenously (IV) at the recommended dosage of 0.8 mg/kg of actual or ideal body weight (whichever is lower) and given once every 6 hours over 4 days for a total of 16 doses. Dose-limiting toxicity of busulfan includes veno-occlusive liver disease, seizures, and coma. To avoid toxicity while ensuring busulfan dose adequacy to completely ablate the bone marrow, IV dosing should be guided by a pharmacokinetic (PK) evaluation of the area under the curve and clearance after the first dose.(2) The PK evaluation should be carried out at the end of the first dose, with results of PK testing available to facilitate dose adjustment before beginning the fifth dose.

Interpretation

Results of the timed collections will be used to calculate a 6-hour area under the curve (AUC). If a different dosing or specimen collection protocol is used, or if different calculations are required, contact the Laboratory Director.

 

The optimal result for AUC (6 hour) derived from this pharmacokinetic evaluation of IV busulfan is 1100 (mcmol/L)(min).

 

Area under the curve results greater than 1500 (mcmol/L)(min) are associated with hepatic veno-occlusive disease. A dose reduction should be considered before the next busulfan infusion.

 

Area under the curve results below 900 (mcmol/L)(min) are consistent with incomplete bone marrow ablation. A dose increase should be considered before the next busulfan infusion.

 

Clearance of busulfan in patients with normal kidney function is usually in the range of 2.1 to 3.5 (mL/min)/kg.

 

Elevated AUC is typically associated with clearance below 2.5 (mL/min)/kg, most frequently due to diminished activity of glutathione S-transferase A1-1 activity.(3)

Clinical Reference

1. Santos GW, Tutschka PJ, Brookmeyer R, et al. Marrow transplantation for acute nonlymphocytic leukemia after treatment with busulfan and cyclophosphamide. N Engl J Med. 1983;309(22):1347-1353

2. Slattery JT, Sanders JE, Buckner CD, et al. Graft-rejection and toxicity following bone marrow transplantation in relation to busulfan pharmacokinetics. Bone Marrow Transplant. 1995;16(1):31-42

3. Slattery JT, Risler LJ. Therapeutic monitoring of busulfan in hematopoietic stem cell transplantation. Ther Drug Monit. 1998;20(5):543-549

4. Czerwinski M, Gibbs M, Slattery JT. Busulfan conjugation by glutathione S-transferases alpha, mu, and pi. Drug Metab Dispos. 1996;24(9):1015-1019

5. Vassal G, Re M, Gouyette A. Gas chromatographic-mass spectrometric assay for busulfan in biological fluids using a deuterated internal standard. J Chromatogr. 1988;428(2):357-361

6. Baselt RC. Disposition of Toxic Drugs and Chemicals in Man. 12th ed. Biomedical Publications; 2020

7. Busulfex. Package insert. Otsuka Pharmaceutical Co, Ltd; Updated January 2015. Accessed October 8, 2024. Available at www.accessdata.fda.gov/drugsatfda_docs/label/2015/020954s014lbl.pdf

8. Palmer J, McCune JS, Perales MA, et al. Personalizing busulfan-based conditioning: considerations from the American Society for Blood and Marrow Transplantation Practice Guidelines Committee. Biol Blood Marrow Transplant. 2016;22(11):1915-1925

Report Available

Same day/1 to 3 days

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

Forms

1. Busulfan Information: Mail-In Specimen Instructions (T559) is required

2. If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.

Mayo Clinic Laboratories | Therapeutics Catalog Additional Information:
mml-antineoplastic, mml-drugmonitoring